Fish Protection System (induced drift application)
Note: This article will be finished with the submission of deliverable 3.3 and 3.4 in October, 2020
Contents
Quick summary
Date: 2018
Developed by: VAW of ETH Zurich
Introduction
The IDA technology provides an alternative approach to improve fish downstream passage at HPPs. Fish damage rates during turbine passage are reduced by specific fish behaviour manipulation prior and during passage using electric fields. The technique works without screening or bypass systems, no specific water losses occur or maintenance measures are required. Constructional efforts are very limited and therefore the IDA technology is well suited for retrofitting at existing HPPs.
Application
The exposure probabilities and intensities of blade strike and shear stresses to fish significantly depend on the actual location where fish enter and pass through the turbine. The technical implementation of the IDA device can be based generally on various behavioural stimuli like light, ultra-sound or electrical fields. Electrical fields are especially favourable due to the fish’s reaction on such. For low field strength, electric fields show repulsive effects on fish. For higher field strength, fish show automatic movement towards the anode (electro-taxis). Moreover, an electrically induced narcosis can occur and persist for a few seconds to a few minutes after field exposure (also called electro-narcosis) depending on the field strength and the exposure time.
For the simplest implementation, the IDA technology builds up a continuous electrical field and guides the fish to the anode, an entry point in the vicinity of the hub, where survival rates are high (see figure 1). Additionally, forcing fish prior to turbine passage into random orientation, e.g. by narcosis, can significantly further support survival of fish during turbine passage. During the FIThydro project a first pilot of the IDA has been tested at a small 35 kW Kaplan turbine in the TUM Lab in Obernach, Bavaria (see figure 2).
First results for the pilot operating in full load are presented in figure 3, showing a reduction of damage rates by about 55 %. The difference with and without IDA device is statistically relevant (Fisher´s exact test, p < 0.01).
Relevant mitigation measures and test cases
Relevant measures | |
---|---|
Fish-friendly turbines | |
Relevant test cases | Applied in test case? |
Altheim test case | - |
Altusried test case | - |
Anundsjö test case | - |
Bannwil test case | - |
Bragado test case | - |
Gotein test case | - |
Guma and Vadocondes test cases | - |
Günz test case | - |
Ham test case | - |
Las Rives test case | - |
Schiffmühle test case | - |
Trois Villes test case | - |
Other information
TUM holds an EU patent for the IDA (EP3029203).
Relevant literature
FIThydro deliverable D3.4 available at https://www.fithydro.eu/deliverables-tech/