Difference between revisions of "Vertical slot fishways"

From FIThydrowiki
Jump to navigation Jump to search
Line 17: Line 17:
  
 
𝑄=𝐶𝑑𝑏𝐻1(2𝑔∆𝐻)0.5
 
𝑄=𝐶𝑑𝑏𝐻1(2𝑔∆𝐻)0.5
<math>Q=C_d*b*H_1*(2g*ΔH)*0.5</math>
+
<math>Q = C_d * b * H_1 * (2g * ΔH) * 0.5</math>
  
 
:Where Q = flow discharge (m3/s)
 
:Where Q = flow discharge (m3/s)

Revision as of 10:07, 26 January 2021

Icon upstream.png
This technology has been enhanced in the FIThydro project! See Innovative technologies from FIThydro for a complete list.

Note: This article will be finished with the submission of deliverable 3.3 and 3.4 in October, 2020

Introduction

Figure 1: Vertical slot fishway in Chatellerault, France.

This type of fishway was developed in North America (Clay, 1961), following several studies on models. The pools may have one or two deep slots (Figure 1), depending on the size of the watercourse and the discharge available. The advantage of having two slots is to be able to increase the flow in the device, instead of an attraction flow injection system or to compensate a moderate head drop at the entrance.

The geometry of cross-walls with deflectors has been the subject of a number of studies ( (Rajaratnam, et al., 1986), (Lenne, 1990), (Larinier, et al., 2002), (Romao, et al., 2017)) and, from the compilation of geometrics characteristics of about thirty vertical slot fishways built in France (Wang, et al., 2010), the dimensions of a typical cross-wall can be proposed (Figure 2):

The flow from the slot is oriented and tends to be directed to the middle of the pool at an angle of 30-45°, resulting in efficient energy dissipation in all the water volume of the pool. When there are two slots, the flow converges and meets in the central section of the pool, creating calm zones on each side of the pool immediately downstream from the walls.

Hydraulic organization of the flows in the pools has also been the subject of numerous studies ( (Rajaratnam, et al., 1986) (Lenne, 1990) (Rajaratnam, et al., 1992), (Wu, et al., 1999), (Puertas, et al., 2004) (Liu, et al., 2006)). Criteria are recently given to obtain a proper organization of the flows in the pools (Wang, et al., 2010). The pool’s length L is generally 7 to 12 times the width of the slot b. For a basin length of 10 b and a fishway slope of 5%-7.5%, a pool’s width B equal to 7-7.5 b could be adopted so as to obtain a two-recirculation zone flow topology and avoid the jet impacting the side opposite the slot. The study of fish behavior (trout and chub) in a ¼ scale vertical slot fishway model, testing different pool width B on slot width b ratios, showed a better rate of fish passage for the two-recirculation zone flow topology than a unique recirculation zone flow topology (obtained when B/b <7). For different pool lengths, one can recommend keeping the same width / length ratio (0.7-0.75). In case of double-slots fishway, the pool width is usually 9 to 10 times b (Larinier, et al., 2002).

A sill can be installed at the base of the slot, especially to limit flow in the device. Sill forces the orientation of the jet to the side opposite the slot, with the hydraulic consequences of reducing the flow topology to one recirculation zone. Moreover, the flows immediately downstream from the sill will tend to plunge (Ballu, et al., 2015).This flow pattern appears less favorable for fishes, after testing with trout on a ¼ scale model (Ballu, 2017). As far as possible, taking into account these experiments, we recommend not installing any sill in the slot.

The flow through a vertical slot fishway can be expressed by the formula:

𝑄=𝐶𝑑𝑏𝐻1(2𝑔∆𝐻)0.5 Failed to parse (syntax error): {\displaystyle Q = C_d * b * H_1 * (2g * ΔH) * 0.5}

Where Q = flow discharge (m3/s)

and

b = width of the slot (m)
H1 = head at the slot (m), i.e. the difference between the water level upstream of the slot and that of the slot crest
g = acceleration due to gravity (9.81 m/s2)
∆H = drop between the two pools (m)
Cd = discharge coefficient of the slot

The coefficient of discharge is dependent on the slot configuration/layout ( (Bombac, et al., 2017; Romao, et al., 2017)), width and the water depth ( (Rajaratnam, et al., 1986) (Wu, et al., 1999), (Fuentes-Pérez, et al., 2014)), the design of the baffle and the global geometry of the pools (Puertas, et al., 2004), the slope (Wang, et al., 2010) or even the presence of sill in slot (Ballu, et al., 2015) or roughness on the bottom of the pool (Ballu, et al., 2017)). In general, it may vary from 0.65 to 0.85, depending of the configuration of these parameters.

The great advantage of the vertical slot fishway is that it can accommodate significant variations in the upstream water level, provided that the level downstream is subjected to similar variations. The conditions of velocity and turbulence remain very stable, whatever the water levels in the fishway, and fish can pass through the fishway, swimming at its preferred depth

Methods, tools, and devices

During planning

During implementation

During operation

Relevant MTDs and test cases

Relevant MTDs
3D fish tracking system
3D sensorless, ultrasound fish tracking
Acoustic Doppler velocimetry (ADV)
Acoustic telemetry
Agent based model
Cassiopee
Current meter
Differential pressure sensor base artificial lateral line probe, iRon
Dilution gauging
FLOW-3D
Guidelines for fishpasses numerical modelling
HEC-RAS
OpenFOAM
Particle image velocimetry (PIV)
Radio frequency identification with passive integrated transponder (PIT tagging)
Radio telemetry
River2D
Sediment simulation in intakes with Multiblock option (SSIIM)
TELEMAC
Visible implant elastomer
Relevant test cases Applied in test case?
Anundsjö test case -
Bannwil test case -
Guma and Vadocondes test cases Yes
Las Rives test case -
Schiffmühle test case Yes

Classification table

Classification Selection
Fish species for the measure 0
Does the measure require loss of power production Operational (requires flow release outside turbine)
-
-
Recurrence of maintenance Irregular at events
Which life-stage of fish is measure aimed at -
-
-
Movements of migration of fish
Which physical parameter is addressed N/A
-
-
-
-
-
-
-
Hydropower type the measure is suitable for Plant in dam
Plant with bypass section
Dam height (m) the measure is suitable for Up to 10
Section in the regulated system measure is designed for In dam/power plant
-
-
-
River type implemented Steep gradient (up to 0.4 %)
Fairly steep with rocks, boulders (from 0.4 to 0.05 %)
Slow flowing, lowland, sandy (less than 0.05 %)
Level of certainty in effect Very certain
Technology readiness level TRL 9: actual system proven in operational environment
Cost of solution See cost table

Relevant literature